RSP 2150
previous next RFS 0070 Relay Switches
  • General Info
  • Features & Benefits
  • Specifications
  • Applications
  • Photos/Video

LNB Redundancy Switch : RSP 2150/2 Sensing Switch

RSP Downloads Downloads   Open/Close

Spec Sheet
RSP 2150


The RSP 2150LNB Redundancy Switch provides two (2x1) L-Band sensing switches for LNB redundancy of both horizontal and vertical polarities on a TVRO satellite. In addition, it provides 24 VDC, enough to power four LNBs. Each L-Band sensing switch contains a single (2x1) RF detector switch which detects the presence of a 950-2150 MHz LNB satellite signal on the primary relay that terminates the off path with 75 Ω. The primary RF input is filtered, amplified and detected to operate the relays. When the input level is above the preset threshold, which is adjustable using the rear panel mounted push buttons, the relays are de-energized and will pass RF even under a no power condition. When the signal falls below the preset threshold, the relay is energized and the secondary signal path is selected. A front panel has been included for each sensing switch to allow manual override to the secondary input. The rear panel has been equipped with 15-pin connectors that provide an interface for contact closure alarms and remote override via contact enclosure

LNB redundancy switch

 

request quote

Features & Benefits

    • The RSP 2150 LNB Redundancy Switch detects loss in signal level from LNB’s & switches to the secondary / back-up if the primary signal level falls below set threshold.

    • Hot swappable power supplies to redundant power LNB’s

    • LNB power feature provides two separately fused power supply modules, each capable of handling 2.5 amps.

    • AC and DC power status is indicated via the front panel mounted LEDs

  RSP 2150/2 LNB Redundancy Switch
Operating Frequency 950-2150 MHz
Impedance 75 Ω
Detected Frequency 950-2150 MHz
RF Detection Level -60 dBm to -20 dBm, adjustable
Frequency Response ± 1.0 dB
Maximum input levels +10 dB
Maximum Input Level (No Damage): +20 dB
Insertion Loss 2.5 dB ± 1.25 dB
Frequency Response ±1.0 dB
Return Loss 12 dB
Isolation 40 dB
Inputs/Outputs Two (2x1)
Manual Override Front panel mounted slide switch
Threshold Adjust Front panel mounted up/down push buttons
Alarm

Form ‘C’ contact closure

Power Requirements 100-240 VAC, 60/50 Hz
Power Consumption 80 W
RF Connectors Type “F”, 75 Ω
Mechanical 2 RU (3.50” H x 19” W x 14” D)
Weight 7.2 lbs gross (boxed) 4.6 lbs net

LNB Redundancy application

  • Front
  • Back

Front

LNB redundancy switch

Back

Drag Mouse Over Image for zoom-in effect

Click drag-right to increase window - click drag-left to decrease. Click drag-up to zoom in. Click drag-down to zoom out

 

 

 

LNB Redundancy Switch w/ Hot-swappable DC Power Supplies

quintech site search button

Request Quote

 

Quick Links               

Products
RF Matrix Guide
Spec Sheets
Software Downloads
Contact Us
Distributors
Download Catalog
Tradeshows
News
RF Conversion Tables

 

Military Solutions Home Page Link