The RPS 18/4.0Q Series Redundant DC Power Supply provides a centralized power source for up to 16 LNAs, LNBs, upconverters, downconverters, line amplifiers, or laser transmitters. The unit is comprised of two separately fused power supply modules configured for nominal voltage or +18 VDC @ 4.0 amps and has been designed for international use with an input voltage of 100-240 VAC, 50/60 Hz. The power supply modules are on individual drawers to provide easy replacement of a failed module. On the rear panel, fuse holders with green LEDs indicate power status for each of the ouput ports.
Two hot-swappable (shared) PSUs on individual drawers
Eliminates costly downtime
Allows scheduled maintenance of receivers without interupting LNB power
Summary alarm via contact closure (standard
|
Insertion Loss |
1 ± 0.5 dB |
|
Frequency Response |
± 1.0 dB |
|
Return Loss |
14 dB |
|
Output Voltage |
+18 VDC |
|
Output Current |
4.0A @ 18 VDC (total load) |
|
Power Requirements |
100-240 VAC, 50/60 Hz (Auto-ranging) • (-48 VDC input power optional) |
|
Power Consumption |
220 W max. |
|
Input Connectors |
Sixteen 2-Pin Quick Disconnects (+VDC and -VDC) |
|
Output Connectors |
Sixteen 2-Pin Quick Disconnects (+VDC and -VDC) |
|
Mechanical |
3 RU (5.25" H x 19" W x 20" D) |
|
Weight |
24.5 lbs. gross (boxed), 19.5 lbs. net |